918.com


021-54179188

Successful Case

Thermal Power Industry

Xintai Power Plant

Jizhong Energy 

Classic Case

Customer:

**** Power Co. Ltd.

Flue Gas Treatment Procedure:

SCR+ESP+FGD

CEMS system:

SDL SCS-900

CEMS question:

  • D2_dish_07.pngSO2 large deviation during whole CEMS calibration;
  • D2_dish_07.pngLarge volume condensed water in pipeline and cooler;

  • D2_dish_07.pngFew ammonia salt deposit;

  • D2_dish_07.pngCan’t pass whole CEMS calibration.

Solution and Application

Solution:

After onsite survey, recommend PreGASS-9500 precondition system without change any situation of existing CEMS, effectively remove the moisture and ammonia in the sample gas, prevent the loss of SO2 and the ammonium salt deposit, improve the response time, meet the national standard requirements, and solve customer problems.

Solution & Test results verification after application

Data comparison: CEMS SO2 test range 0-100mg/m3

ItemSO2 standard gas Con.T90 (s)SO2 reading (mg/m3)Error of whole CEMS calibration%
Before PreGASS modification36.0mg/m³>>20020.0mg/m³ 10.6%
77.8mg/m³>>20059.2mg/m³12.4%
134.4mg/m³ >>200110.0mg/m³ 16.2%
After PreGASS modification36.0mg/m³13036.2mg/m³ 0.13%
77.8mg/m³ 12379.0mg/m³0.8%
134.4g/m³125134.0mg/m³0.26%

Result & Performance:

15 days from onsite survey & installation & commissioning acceptance, T90<130s, deviation error of whole CEMS calibration <±2.5%.        


XML地图